Files
Piik/docs/research/native-shared-encode-sender.md
T

34 KiB

Native Shared-Encode Sender

  • Research date: 2026-08-19
  • Scope: one Windows game-capture sender, one encoded video stream, and at most two independent standard WebRTC media edges
  • Status: stacked Draft PRs #16/#18/#22/#23/#25/#28 pass one bounded live two-leg WebCodecs/Pion candidate. Both product-wiring attempts remain no-go-unclassified; product and physical shared encoding remain unproven.

Decision Input

TeamSpeak-style shared encoding is a required later sender phase. It can remove duplicate host encoding work, but it cannot remove the upload copy, RTP state, or congestion control required by each outgoing edge. The first implementation must prove one narrow property before adding capture, audio, UI, or packaging:

Two unmodified browser viewers receive two independent WebRTC sessions while one physical encoder invocation produces the compatible encoded access unit consumed by both sessions.

The completed Pion/WebCodecs research ladder proves a narrower property: one JavaScript VideoEncoder object emitted the encoded chunks consumed by two browser sessions. WebCodecs does not expose physical encoder-instance counts, and Chrome used hardwareAcceleration: "no-preference" after rejecting the single allowed prefer-hardware attempt. The result therefore must not be described as one hardware or physical encode.

The preferred first experiment is a standalone Windows C++ sender using a fixed libwebrtc revision. It keeps libwebrtc's mature PeerConnection, RTP/RTCP, pacing, NACK/RTX, DTLS-SRTP, ICE, and TURN behavior on each edge. Electron is not part of the media experiment; it can only wrap a proven helper later.

Minimal Risk Spike

existing Node signaling
        |
Windows sender.exe
synthetic source -> shared encoder coordinator -> encoder proxy A -> PC A -> browser A
                                      `--------> encoder proxy B -> PC B -> browser B
  • Windows x64, C++, video-only, fixed 720p30, and exactly two outgoing edges.
  • Inject a custom VideoEncoderFactory into libwebrtc. It returns two proxy encoders, one for each normal send pipeline.
  • Each proxy keeps its own EncodedImageCallback; one coordinator owns the physical counting encoder.
  • The coordinator deduplicates matching input-frame timestamps and publishes the same reference-counted encoded buffer to both callbacks.
  • Reject the second edge when codec, profile, dimensions, or layer configuration differ. Never hide incompatibility by creating a second physical encoder.
  • For this fixed single-layer spike only, aggregate the two SetRates() requests by taking the minimum total target bitrate and frame rate, bounded by the selected profile. This is an experiment safety policy, not a product design: one weak edge can lower a healthy edge, so productization is forbidden. Independent quality requires another representation, an accepted scalable design, or transcoding.
  • Coalesce PLI/keyframe requests so one physical keyframe is delivered to both packetizers. RTP sequence numbers, SSRC, TWCC, pacing, retransmission caches, RTCP, DTLS-SRTP, and ICE remain independent per edge.

libwebrtc officially permits an application to inject a VideoEncoderFactory and defines VideoEncoder::Encode, SetRates, loss/RTT notifications, and the encoded callback. It does not promise cross-PeerConnection shared encoding. The proxy/coordinator design is therefore an inference that this spike must validate, not a supported feature claim.

Stop the libwebrtc route if two send pipelines produce incompatible cadence, timestamps, adaptation, or callback behavior and correctness would require a fork of VideoStreamEncoder, RtpVideoSender, or another libwebrtc internal. Do not carry a permanent media-engine fork for this feature.

Capture And Hardware Encoding Come Later

Only after the synthetic two-edge property passes:

  1. Capture a window or display with Windows Graphics Capture into a D3D11 surface.
  2. Convert BGRA to NV12 once. Do not claim zero-copy until profiling proves the actual texture path.
  3. Enumerate hardware Media Foundation H.264 encoders with MFTEnumEx and MFT_ENUM_FLAG_HARDWARE, then probe every required input/output type and ICodecAPI control. Enumeration alone is not a capability guarantee.
  4. Require proven support for low-latency operation, runtime bitrate control, and explicit keyframe requests; reject that adapter instead of silently weakening the contract when a property is unavailable or read-only.
  5. Request one H.264 Constrained Baseline, packetization-mode 1 stream, then inspect the emitted SPS and negotiated profile-level-id before accepting the path. Browser baseline interoperability does not guarantee a particular hardware MFT or 1080p60; test every target GPU/browser combination.

Audio, per-process WASAPI capture, WGC/DDA fallback, source selection, Electron, installers, updating, and cross-platform abstractions stay outside the first spike.

2026-08-20 Windows codec comparison

The target workstation exposes an NVIDIA GeForce RTX 4070 SUPER. NVIDIA's published NVENC contract encodes H.264, HEVC, and AV1, but not VP8. The current Native canary instead fixes VP8 and asks WebCodecs for prefer-hardware; its code removes that preference when the capability check rejects it. The prior bounded run did reject the preferred configuration and continued with no-preference. One VideoEncoder and its first output callback therefore do not establish hardware encoding, and VP8 cannot use this GPU's NVENC engine.

Discord and the read-only Oopz 0.87.425 package inspection both make H.264 the smallest Windows hardware candidate. Discord publishes native OS/driver capture and encoding with hardware preferred and WebRTC transport. Oopz's package contains Agora screen-share integration, WGC/DXGI/D3D11 capture components, an H.264 Web viewer configuration, NVENC/QSV/AMF plus software codec paths, and an observable hardware-acceleration field. The inspection found one channel screen publication and no evidence of an application-owned per-viewer PeerConnection loop. That is consistent with a common publication, but static packaging cannot prove one physical encoder, the codec/profile selected for a real host, or actual GPU use.

The bounded WebCodecs H.264 run, its no-go result, and the hardware-only Media Foundation successor are owned by Native H.264 hardware decision spike. Do not recreate a codec ladder here. AV1 waits for the same physical-encode proof and the desktop/mobile Viewer decode matrix; compression efficiency alone cannot advance it.

Reproducibility anchors for the proprietary-package inspection, without copied code or user data:

  • Oopz data/app.so: SHA-256 462E081D03E49008AD8D64A032BD6396F0B97CDADBDF715F7C6810D081A714F8.
  • Oopz screen-viewer bundle screenShare/page/assets/index-C6S4n49C.js: SHA-256 1EAECD2C0DC332E5D2628047EE1BECB874C8130C2C383355EE313961EFC6E1CA.
  • Oopz agora_rtc_sdk.dll: SHA-256 66B8B34A57BA0EE9DCC6C516E2CC20F5F1EB5D35ED7150FDF37201A46BC8D4A0.

Pion Validation Route

Pion is the released-public-API validation route while the larger libwebrtc encoder-proxy experiment remains unbuilt. TrackLocalStaticSample owns one packetizer and writes through a TrackLocalStaticRTP that can bind to multiple PeerConnections, making encoded-payload fanout explicit.

This certainty moves more responsibility into the application. Pion's default interceptors provide NACK, RTCP reports, statistics, and transport-wide feedback, but an external encoder still needs explicit send-side bandwidth estimation, aggregation of both edge targets, encoder bitrate control, PLI handling, and bounded RTP/RTX queues. The already bounded #23/#28 ladder uses the same minimum-edge safety rule and must not invent a custom SRTP, ICE, or congestion protocol. A product route must follow ADR-0007 instead.

Fixed-HIGH Product-Wiring Attempt

ADR-0006 retains one narrow candidate: fixed VP8 1280x720@30 with a 3 Mbps ceiling, one WebCodecs encoder object, at most two independent Pion legs, the strict ordinary signaling wire, unmodified viewers, read-only feedback, and no audio or automatic LOW. This is a proposed test boundary, not current product behavior or hardware-encoder evidence.

The 2026-08-20 local delivery checkpoint rebases that candidate onto the sole current access contract: screener-v2, site-access Cookie authentication, explicit private-link creation, fragment-only Viewer grants returned to the local Host, and STUN-only ordinary ICE. Native creation alone requests a fixed 300-second provisional room. It remains random and memory-only even with SQLite configured: the current Host session suppresses the reclaim deadline, its generation-matched disconnect resets the five-minute window, the ordinary transient room TTL still caps the room, and restart drops it. A pre-auth connection or authentication failure gets one same-room/token/client-generation retry without a second room POST. SQLite remains v2 and ordinary Web creation is unchanged. Android stop/capture-failure cleanup keeps the established signaling socket until its single-thread teardown sends abandon-room and then performs a normal close; pending-work cancellation only blocks callbacks and cancels active HTTP. No ACK is awaited. A provisional room whose WebSocket handshake never opened remains bounded by the existing 300-second reclaim window. HTTP statuses, Cookie attributes, create-room responses, Host authentication, and ignored Viewer evidence are strict and bounded; errors retain only fixed categories. Focused Go and TypeScript checks pass. The overbroad unused gate/probe framework stays deleted; the current command consumer is limited to the executable runner and sanitized stage ledger required by the next authorized run.

The one authorized 2026-08-20 current-wire attempt used Chrome 151 on Windows amd64, a temporary non-default Chrome profile, a real animated Chrome tab, and an isolated local Node server with an in-memory RoomStore and peer assistance disabled. It did not contact production or SQLite. Retained history booleans show that the source and Sender pages loaded and no Viewer page was created. The runner reported failedStage=node-host after its bounded 20-second Sender-start interval because it did not observe the combined Sender-ready and Go source-RTP condition.

This is no-go-unclassified, not evidence that the Node Host path itself failed. The timeout branch did not retain a final Sender DOM/counter sample, so it cannot locate the break among getDisplayMedia request/resolve, Host admission/create, WSS authentication, local bridge connection, first encoded chunk, or Go source RTP. There was no retry or timeout adjustment. Viewer auth, offer/answer/ICE, Pion bound-edge output, Viewer inbound/decode/render, two-edge, and FIFO evidence were never attempted. A later run needs separate authorization and an unconditional stage-1 final-negative ledger before it may create one Viewer.

That local-only runner is now the current npm run gate:native-one-viewer consumer. It requires an explicit Chrome executable environment path and uses the task-local Go executable or task-specific PATH; neither path is committed. Each monotonic Sender-start transition appends and flushes one bounded JSON record containing only booleans and capped counters. A pure timeout test proves that capture, admission/create, Host WSS, bridge, fixed-HIGH, first encoded chunk, Go-ingest, and source-RTP state cannot be erased by a later failed sample. The one-Viewer signaling/media waits likewise preserve their latest sanitized sample in the final report. They now accept evidence only from one frozen signaling socket/auth/opaque-connection ordinal, one PeerConnection/video-track ordinal, and the same Pion slot/edge generation across signal and media stages. The raw connection ID remains page-local. Every CDP RPC/sample is capped by the remaining stage deadline. Final status is written only after bounded process-tree exit and closed-port polling, followed by an exact system-Temp path audit, recursive reparse-point rejection, profile deletion, and absence verification; any cleanup failure is fail-closed. Microsoft documents /T as terminating a task's child processes and ReparsePoint as the filesystem attribute used for these special entries. Pure tests cover hung sampling, cross-PC evidence, cleanup-before-pass, profile path bounds, and deletion failure. Sources were rechecked 2026-08-20.

One separately authorized second current-wire run used the frozen gate once and did not retry or adjust a threshold. Its append-and-flush ledger reached sequence 7 and retained positive booleans for capture request/resolution, site access, private room creation, Host WSS authentication, bridge readiness, fixed VP8 1280x720@30/3 Mbps config acceptance, one encoder object, and entry into the first WebCodecs output callback. The ledger serialized zero media counters but did not retain whether diagnostics arrived, so those values do not prove that Go reported zero. The runner failed closed at sender-start; it never created the Viewer page and did not exercise Viewer auth, SDP/ICE, Pion bound-edge output, decode/render, a second Viewer, or FIFO. Cleanup was complete before the report was finalized: Chrome and Native exited, the isolated Node listener and all three random loopback ports closed, and the exact task profile passed a non-reparse audit and was removed.

The result narrows but does not classify the break. The gate increments its encoded-output observation before it calls the product output callback, and that run did not retain whether the current local media WebSocket attempted, returned from, or threw during the binary frame send. Static source comparison shows a matching binary message type, 17-byte big-endian header, one-MiB payload limit, and VP8 frame decode on both sides. A focused test now drives the real local /media WebSocket through ready, fixed config acceptance, one same-contract binary frame, decode, fanout, and positive framesWritten plus source-RTP packet accounting. Pion's unbound static RTP track also returns no error. This proves the current envelope is consumable by the current Go handler; it does not prove that the retained browser called or returned from the product send.

The concrete P1 defect at this boundary was silent handling of every unexpected post-config WebSocket read error. The handler now emits one fatal with fixed message local media bridge read failed only while the app context is active and the close status is neither normal nor going-away. It never includes the underlying error or close reason. Focused real-WebSocket tests cover an abnormal post-config close, normal close, and app shutdown. All Go tests, vet, Windows amd64 no-CGO build, TypeScript typecheck, and the relevant bridge probe/ledger tests pass.

One authorized evidence-clarification run then used the corrected tracked gate exactly once with the same fixed VP8 1280x720@30, 3 Mbps, one-Viewer boundary, Chrome 151, one in-memory loopback room, and no peer assistance. It retained the start sequence through one generation-1 binary super.send() return, then observed no diagnostics or post-send diagnostics, zero encoder errors, and at least one sanitized fatal marker. The media-counter zeros are initial ledger values, not Go reports. The gate failed at sender-start and did not create a Viewer.

Cleanup passed 5/5 before final failure. No retry, threshold change, H.264, second Viewer, FIFO, or production run followed. The result remains no-go-unclassified: the fatal marker and missing diagnostics do not prove where or why the product path stopped, so no underlying close or raw cause may be inferred.

A later static follow-up identified a deterministic source fatal candidate, but the retained run did not preserve the fatal category needed to attribute its failure to that branch. WebCodecs defines EncodedVideoChunk.duration as nullable and copies output timestamp and duration from the input VideoFrame; it does not establish the prior product assumption that the next timestamp must be at least the previous timestamp plus duration. The local sender substitutes 33,333 microseconds when duration is absent, so ordinary capture jitter such as 1,000,000 then 1,033,000 microseconds previously reached encoded frame timestamps overlap despite strictly increasing source time.

The source candidate now packetizes the first frame without advancing Pion's clock, then advances it by each positive adjacent source-timestamp delta before packetizing the next frame. Reported duration remains only for positive dropped-source-time diagnostics; equal or decreasing timestamps still fail closed. Focused timeline tests cover shorter-than-duration jitter, dropped source time, non-increasing input, and a positive delta below one 90 kHz sample. A real /media handler test carries the two jittered frames through decode and fanout with two frames written and positive source RTP. All Native Go packages pass. These checks prove that specific fatal path is removed; the later bounded loopback smoke below supplies one Viewer delivery proof but does not classify the retained fatal run or establish broader Native acceptance. The WebCodecs and pinned Pion packetizer sources were rechecked 2026-08-20.

A bounded follow-up smoke on 2026-08-20 then exercised the complete one-viewer loopback path with Chrome 151, fixed VP8 1280x720@30, and peer assistance off. The Sender reached 30 written frames and 85 source RTP packets with zero fatal or encoder errors. The Viewer authenticated, completed offer/answer/ICE, received 877 packets (842,346 bytes), and advanced from 0 to 299 decoded and rendered frames at 1280x720. The gate stopped only because its Pion outbound check sampled the same two-second diagnostics snapshot before it refreshed (pionPacketDelta=0); that residual probe timing does not invalidate the independent inbound/decode/ render counters, but it leaves a fresh Pion outbound delta unretained.

The gate probe now treats trickled candidates before the first offer, and a development-only pre-offer control-socket replacement, as one logical generation; after an active offer/PeerConnection, socket or connection changes still fail closed. This is test-harness evidence, not a runtime protocol relaxation. No second Viewer, FIFO, hardware, endurance, public-network, or packaged-native run followed.

The frozen probe continues to bind the first actual local media WebSocket as gate-local generation 1. A second bridge generation saturates at 2, stops accumulating the first generation's counters, and fails the Viewer signal, Viewer media, and final-success checks. Pure tests cover success, throw, and late replacement without retaining a URL, payload, token, SDP, candidate, IP address, or raw error.

Chromium documents the tab-capture auto-selection switch as a test-only aid, and Chrome requires a non-default user-data directory for remote debugging from Chrome 136. Those constraints explain the isolated harness setup; they do not prove that getDisplayMedia resolved in the first failed current-wire run. Static inspection of the pinned Pion v4.2.18 TrackLocalStaticRTP.WriteRTP shows that it iterates the current bindings and returns no error for an empty binding set. This excludes a pre-Viewer no-binding write as the likely fatal break; it is not runtime proof of Go ingest or source RTP. Sources were rechecked 2026-08-20.

The earlier authorized 2026-08-19 local product gate is no-go-unclassified:

Checkpoint Retained evidence
Ordinary Node server The local listener started with peer assistance and TURN disabled. No raw signaling frames were retained.
Native room/host /api/start returned an invite, which in the attempted branch followed room creation and host signaling authentication.
Local encoder Config acknowledgement preceded construction; the probe observed one VideoEncoder object and encoded output. Helper ingress, frame decode, and source RTP were not proven.
Viewer page The page and probe loaded, but the 30-second combined decoded-and-rendered condition timed out.
Downstream lifecycle Viewer auth, peer-joined, SDP/candidates, PC states, source RTP/edge packets, inbound RTP, video readiness, and console state were not retained.

For that retained run, the first missing evidence checkpoint was viewer authentication, not a proven authentication failure. The harness discarded each false sample; its reused progress() path can omit a connection after a swallowed getStats() error; and render evidence had no readiness/current-time/video-dimension fallback. The timeout therefore cannot locate the runtime break or rule out a probe-only false negative. The static code review found no obvious protocol disconnect, which is not runtime evidence.

No second viewer, two-edge proof, third-viewer waiting/FIFO promotion, or direct/TURN pair ran. Do not treat the attempted branch as usable or mergeable product code. ADR-0006 owns the separately authorized staged revalidation and exact stop line; this research does not redefine it.

Stacked Validation Ladder

These Draft PRs are deliberately stacked research, not six product features:

PR / commit Bounded gate Result
#16 / 5b09f0a One Pion RTP write across two independent transports Equivalent payload reached two transport-local SSRCs. There was no encoder or browser.
#18 / 80f65d0 Synthetic WebCodecs VP8 chunks through Pion to two Chrome receivers One encoder object produced 120 inputs/outputs and both browsers decoded; this was an offline fixture, not physical-encode evidence.
#22 / 8121b69 Continuous 320x180@30 live bridge for about 12 seconds One encoder object sent 360 chunks; each viewer decoded and presented 331 frames, with encoder/native queue peaks of one.
#23 / eb9aabe Merged PLI/FIR policy, min-of-two target policy, and independent 512-packet NACK/RTX state Policy traces passed, but stock Pion GCC plus negotiated RTX failed with unknown ssrc: 2001. This composition is no-go.
#25 / a6c3456 No-RTX primary-SSRC replay under one controlled leg loss Leg 1 emitted one NACK and one replay with fresh TWCC, then decoded another 278 frames; leg 2 stayed clean. This can distort RTCP loss accounting.
#28 / aad560e Live two-leg stock-GCC target applied to the same encoder object, then one controlled loss The bounded gate passed. Both estimates happened to be 600 kbps, so heterogeneous-estimate behavior remains unproven.

Final Live Gate Evidence

The sole authorized #28 browser run used Headless Chrome 151 and Pion WebRTC v4.2.18 on Windows amd64. It ran 1280x720@30 for 12.972 seconds with 390 scheduled inputs and 390 outputs from one VideoEncoder object. The encoder queue peaked at 1/4, the native queue at 1/8, and the WebSocket buffer at 12,467/524,288 bytes; no encoder or socket drop occurred.

Both legs returned real Transport-CC before target selection. Their final stock GCC estimates were both 600 kbps. The coordinator took the minimum, published one 600 kbps target, and the host serialized flush(), configure() on the same encoder object, and a forced key frame to acknowledge the change from the initial 1.2 Mbps ceiling.

After acknowledgment, the boundary dropped one leg-1 primary packet. Chrome sent one NACK and Pion replayed the same primary RTP identity with a new TWCC sequence; leg 2 recorded no drop, NACK, or replay. Both viewers decoded another 359 frames after the shared recovery marker. This is a go result only for the bounded live target plus primary-SSRC recovery candidate.

Product Quality Direction

PR #28 establishes only that one live VideoEncoder object accepted one conservative feedback-derived reconfiguration while feeding two transports. It does not establish heterogeneous feedback behavior and must not evolve into a room-wide minimum controller.

ADR-0007 keeps stock WebRTC GCC per direct/peer path. Each SFU path starts with a HIGH ceiling and built-in BWE selects from one shared HIGH+LOW pair. App evidence affects topology eligibility and diagnostics, not ordinary layer selection. LOW may already be active, and idle stop depends on the resource gate. The active representation/layer limit is two, never one per viewer; the host still has at most two downstream media edges.

If a qualified hardware/power-efficient LOW path is unavailable or its measured encoder/CPU/GPU game or upload load is unacceptable, LOW fails closed for weak paths while healthy paths keep HIGH. LOW may remain active when that measured budget passes; stopping it while idle is an optimization.

The app's HIGH/FALLBACK states and asymmetric windows only classify topology eligibility, not media layers, and do not form a composite score. Viewer requests are authenticated, rate-limited, deduplicated advice and need sender transport/encode plus viewer receive/decode corroboration. UA and device identity do not participate.

A native relay forwards the selected encoded packets and must not decode or re-encode them. An ordinary non-scalable representation cannot be forwarded into a second quality; the bounded choices are a second encode, SVC, or transcoding. ADR-0007 statically closes current Web P2P simulcast and Web/LiveKit SVC as cross-path shortcuts, but keeps pinned LiveKit exactly-two simulcast with built-in SFU bandwidth adaptation on zero-descendant leaves as the priority runtime candidate. A root-with-children downshift/evacuation gate must pass before default enablement. Explicit subscriber quality is next if built-in selection fails; manual sender activation follows if always-on cost fails; custom/native dual encode is last. A future native SVC decision may reopen only with an explicit hardware encoder contract, at most two decodable layers, one encoded output reused across direct/peer/SFU, independent path selection, and the real game/power matrix. Media Capabilities or RTCStats power-efficiency signals are diagnostics, not hardware proof; an unestablished path stays disabled rather than silently using software. Future dual-tree/striped distribution may reduce two-copy host upload toward one copy plus redundancy, but does not block dual-representation work.

Simulcast does not change this native proof boundary: one sender may negotiate HIGH/LOW, but separate direct PeerConnections have no portable shared-encode contract and inactive API state is not physical resource proof. ADR-0007 and Realtime Quality Adaptation own the static standard-path results and any future native reopen gate. This path still requires measured per-representation traffic/resources and cannot bypass #28's stock-GCC/RTX stop line.

2026-08-21 Evaluation Packaging Boundary

The current source now has one Windows x64 evaluation-package path. It reuses the existing Go build and MSVC helper build, places the two executables beside each other, embeds the exact Git revision, adds an internal SHA256SUMS.txt, and publishes the ZIP with an adjacent SHA-256 file. screener-sender.exe --version is the non-interactive package smoke. This does not add an installer, Electron, auto-update, signing, a bundled server, codec matrix, or release.

The workflow uses the official windows-latest image, whose current manifest includes VSWhere, the x64 Visual C++ tools, and Windows 11 SDK, and the official immutable actions/upload-artifact@v7 path with missing-file failure, zero second-stage compression for the precompressed ZIP, and seven-day retention. GitHub requires authentication to download the resulting artifact. The workflow is path-filtered on pull requests and main, with manual dispatch for an exact retained commit. Sources were checked 2026-08-21.

The linked-binary audit covers 23 modules: coder/websocket is ISC; the 16 Pion modules are MIT; google/uuid, wlynxg/anet, and the four golang.org/x modules are BSD-style. Every linked module exposes a recognized root license file. The packager derives the list from go list -deps, copies those exact files plus the Go toolchain license, and fails if a linked module has no license file. No GPL/AGPL reference or proprietary Oopz code enters the package.

The project distribution license remains undecided. The Actions artifact is therefore labeled evaluation-only and grants no project redistribution right; GitHub Release publication remains blocked on the license decision. This bounded trial artifact does not change ADR-0006's product No-Go status.

Product Stop Line

The stock Pion GCC plus negotiated RFC 4588 RTX composition is no-go-stock-pion-gcc-rtx; do not work around it with a custom pacer, congestion controller, interceptor fork, or private transport. The no-RTX primary-SSRC path stays research-only because it sacrifices retransmission- specific receiver statistics and can distort RTP/RTCP loss accounting.

No stacked PR is connected to Screener's product path, capture path, or audio path. Before product consideration, a target native sender must still prove one physical encoder invocation on representative hardware, live PLI/FIR-to-encoder control, heterogeneous downstream estimates, bounded burst and sustained loss, audio/A-V synchronization, reconnect isolation, browser diversity, lifecycle, and sustained CPU/GPU, memory, latency, quality, and upload measurements. A third host edge, custom RTP/SRTP, or a custom congestion-control framework remains out of scope. The #28 minimum-of-two policy is also out of scope for product code; retaining its evidence does not retain its policy. Ordinary Web and Native peer ICE stays STUN-only; optional selected-edge TURN follows the shared controller only after SFU/UDP fails and needs its own bounded transport gate.

Primary Sources And License Boundary

The current Go candidate directly uses Pion (MIT) and coder/websocket (ISC). The evaluation package generates and verifies notices for the Go runtime and all linked direct/transitive dependencies. Choose the project license before a formal release or redistribution grant. libwebrtc/H.264 remains a separate future route requiring its own third-party notice and patent/licensing review. No source code from these projects was copied into Screener.