Native Shared-Encode Sender
- Research date: 2026-08-19
- Scope: one Windows game-capture sender, one encoded video stream, and at most two independent standard WebRTC media edges
- Status: stacked Draft PRs #16/#18/#22/#23/#25/#28 pass one bounded live two-leg WebCodecs/Pion candidate. Both product-wiring attempts remain no-go-unclassified; product and physical shared encoding remain unproven.
Decision Input
TeamSpeak-style shared encoding is a required later sender phase. It can remove duplicate host encoding work, but it cannot remove the upload copy, RTP state, or congestion control required by each outgoing edge. The first implementation must prove one narrow property before adding capture, audio, UI, or packaging:
Two unmodified browser viewers receive two independent WebRTC sessions while one physical encoder invocation produces the compatible encoded access unit consumed by both sessions.
The completed Pion/WebCodecs research ladder proves a narrower property: one
JavaScript VideoEncoder object emitted the encoded chunks consumed by two
browser sessions. WebCodecs does not expose physical encoder-instance counts,
and Chrome used hardwareAcceleration: "no-preference" after rejecting the
single allowed prefer-hardware attempt. The result therefore must not be
described as one hardware or physical encode.
The preferred first experiment is a standalone Windows C++ sender using a fixed libwebrtc revision. It keeps libwebrtc's mature PeerConnection, RTP/RTCP, pacing, NACK/RTX, DTLS-SRTP, ICE, and TURN behavior on each edge. Electron is not part of the media experiment; it can only wrap a proven helper later.
Minimal Risk Spike
existing Node signaling
|
Windows sender.exe
synthetic source -> shared encoder coordinator -> encoder proxy A -> PC A -> browser A
`--------> encoder proxy B -> PC B -> browser B
- Windows x64, C++, video-only, fixed 720p30, and exactly two outgoing edges.
- Inject a custom
VideoEncoderFactoryinto libwebrtc. It returns two proxy encoders, one for each normal send pipeline. - Each proxy keeps its own
EncodedImageCallback; one coordinator owns the physical counting encoder. - The coordinator deduplicates matching input-frame timestamps and publishes the same reference-counted encoded buffer to both callbacks.
- Reject the second edge when codec, profile, dimensions, or layer configuration differ. Never hide incompatibility by creating a second physical encoder.
- For this fixed single-layer spike only, aggregate the two
SetRates()requests by taking the minimum total target bitrate and frame rate, bounded by the selected profile. This is an experiment safety policy, not a product design: one weak edge can lower a healthy edge, so productization is forbidden. Independent quality requires another representation, an accepted scalable design, or transcoding. - Coalesce PLI/keyframe requests so one physical keyframe is delivered to both packetizers. RTP sequence numbers, SSRC, TWCC, pacing, retransmission caches, RTCP, DTLS-SRTP, and ICE remain independent per edge.
libwebrtc officially permits an application to inject a VideoEncoderFactory
and defines VideoEncoder::Encode, SetRates, loss/RTT notifications, and the
encoded callback. It does not promise cross-PeerConnection shared encoding.
The proxy/coordinator design is therefore an inference that this spike must
validate, not a supported feature claim.
Stop the libwebrtc route if two send pipelines produce incompatible cadence,
timestamps, adaptation, or callback behavior and correctness would require a
fork of VideoStreamEncoder, RtpVideoSender, or another libwebrtc internal.
Do not carry a permanent media-engine fork for this feature.
Capture And Hardware Encoding Come Later
Only after the synthetic two-edge property passes:
- Capture a window or display with Windows Graphics Capture into a D3D11 surface.
- Convert BGRA to NV12 once. Do not claim zero-copy until profiling proves the actual texture path.
- Enumerate hardware Media Foundation H.264 encoders with
MFTEnumExandMFT_ENUM_FLAG_HARDWARE, then probe every required input/output type andICodecAPIcontrol. Enumeration alone is not a capability guarantee. - Require proven support for low-latency operation, runtime bitrate control, and explicit keyframe requests; reject that adapter instead of silently weakening the contract when a property is unavailable or read-only.
- Request one H.264 Constrained Baseline, packetization-mode 1 stream, then
inspect the emitted SPS and negotiated
profile-level-idbefore accepting the path. Browser baseline interoperability does not guarantee a particular hardware MFT or 1080p60; test every target GPU/browser combination.
Audio, per-process WASAPI capture, WGC/DDA fallback, source selection, Electron, installers, updating, and cross-platform abstractions stay outside the first spike.
2026-08-20 Windows codec comparison
The target workstation exposes an NVIDIA GeForce RTX 4070 SUPER. NVIDIA's
published NVENC contract encodes H.264, HEVC, and AV1, but not VP8. The current
Native canary instead fixes VP8 and asks WebCodecs for prefer-hardware; its
code removes that preference when the capability check rejects it. The prior
bounded run did reject the preferred configuration and continued with
no-preference. One VideoEncoder and its first output callback therefore do
not establish hardware encoding, and VP8 cannot use this GPU's NVENC engine.
Discord and the read-only Oopz 0.87.425 package inspection both make H.264 the smallest Windows hardware candidate. Discord publishes native OS/driver capture and encoding with hardware preferred and WebRTC transport. Oopz's package contains Agora screen-share integration, WGC/DXGI/D3D11 capture components, an H.264 Web viewer configuration, NVENC/QSV/AMF plus software codec paths, and an observable hardware-acceleration field. The inspection found one channel screen publication and no evidence of an application-owned per-viewer PeerConnection loop. That is consistent with a common publication, but static packaging cannot prove one physical encoder, the codec/profile selected for a real host, or actual GPU use.
The bounded WebCodecs H.264 run, its no-go result, and the hardware-only Media Foundation successor are owned by Native H.264 hardware decision spike. Do not recreate a codec ladder here. AV1 waits for the same physical-encode proof and the desktop/mobile Viewer decode matrix; compression efficiency alone cannot advance it.
Reproducibility anchors for the proprietary-package inspection, without copied code or user data:
- Oopz
data/app.so: SHA-256462E081D03E49008AD8D64A032BD6396F0B97CDADBDF715F7C6810D081A714F8. - Oopz screen-viewer bundle
screenShare/page/assets/index-C6S4n49C.js: SHA-2561EAECD2C0DC332E5D2628047EE1BECB874C8130C2C383355EE313961EFC6E1CA. - Oopz
agora_rtc_sdk.dll: SHA-25666B8B34A57BA0EE9DCC6C516E2CC20F5F1EB5D35ED7150FDF37201A46BC8D4A0.
Mobile Sender Boundary
Android now has one parallel P1 source slice; it does not broaden ADR-0006's Windows scope and does not create a cross-platform sender framework. Mobile Web Host remains unsupported. The accepted native slice targets Android 14/API 34+ and the flagship peer-assisted Host direct-child path.
Android's official MediaProjection path captures the display into a Surface;
selected-app-window capture starts with Android 14 QPR2. API 34 requires fresh
consent for each session, one use of each projection token, and a foreground
service declared as mediaProjection. Rotation or selected-content resizing requires
onCapturedContentResize() handling; user stop, screen lock, another projection,
or process death invalidates the session and requires bounded cleanup through
onStop(). These OS consent and foreground indicators are part of the product
experience and cannot be made invisible.
The bounded Android data path is:
MediaProjection -> libwebrtc ScreenCapturerAndroid
-> HardwareVideoEncoderFactory (VP8/H.264 only, no software fallback)
-> existing site access / room / WSS / peer-assisted direct assignment
-> at most two unmodified Web viewers
The slice uses the public libwebrtc Android API rather than hand-building capture,
RTP, pacing, congestion control, or SRTP. DefaultVideoEncoderFactory is excluded
because it composes hardware with software fallback; a filtered
HardwareVideoEncoderFactory exposes only VP8/H.264. It adds no mobile-only
topology, audio, LOW, AV1, codec ladder, third downstream edge, SFU publisher,
selected-edge TURN, or software fallback. Direct children are authoritative by
route revision and connection generation. A requested SFU publication returns
one bounded route-failed; it is not reported as supported.
The first functional target is 720p30 at a 3 Mbps ceiling. Codec name and Android hardware metadata are admission signals, not performance proof. Once the source slice closes, one device/one Viewer smoke checks consent, selected encoder, first frame and cleanup. Rotation hot-resize, application audio, network reselection, thermal/power and multi-Viewer matrices follow later; they do not block source landing and cannot silently enable software encoding. Network changes reuse the existing per-edge WebRTC recovery contract rather than restarting capture or creating a new transport.
Activity recreation does not yet reattach to an active foreground service. After rotation or process recreation, controls can show their initial state while the service continues sharing; its duplicate-start gate still prevents a second session. Restoring service status is a later P2 lifecycle task, not a media-path requirement for this source slice.
The pinned webrtc-sdk/android packaging project is MIT-licensed and bundles
upstream libwebrtc under its BSD-style license and PATENTS terms. OkHttp and
kotlinx.serialization are Apache-2.0. The slice copies no implementation from
LiveKit or another sender. A future distributed APK must retain the applicable
third-party notices and still waits on Screener's project-license decision.
OkHttp 5.3.0 resolves Kotlin stdlib 2.2.21. Android's current compatibility table requires AGP 8.10 or newer for Kotlin 2.2 class files, and AGP 8.10 uses Gradle 8.11.1 plus JDK 17. The source therefore pins Kotlin 2.2.21, AGP 8.10.1, Gradle 8.11.1, compile SDK 35 and JDK 17 rather than relying on an IDE default.
iOS work remains later and separate. Apple's current ScreenCaptureKit
documentation says the framework replaces ReplayKit for screen streaming and
that a broadcast extension is no longer required, but the iOS sample requires
iOS 27 and the current APIs are still beta. Screener therefore does not build a
ReplayKit/Broadcast Upload Extension compatibility stack. After the final iOS
27 SDK and stable OS ship, one narrow ScreenCaptureKit system-picker spike may
feed a fixed-HIGH VideoToolbox encoder into the same one/two-Web-viewer
contract. It must set
kVTVideoEncoderSpecification_RequireHardwareAcceleratedVideoEncoder and verify
kVTCompressionPropertyKey_UsingHardwareAcceleratedVideoEncoder; otherwise it
fails closed. Rotation, background execution, lock-screen behavior, network
switching, thermal throttling, audio scope, and A/V sync remain explicit gates
on real devices, not implied framework capabilities.
Pion Validation Route
Pion is the released-public-API validation route while the larger libwebrtc
encoder-proxy experiment remains unbuilt. TrackLocalStaticSample owns one
packetizer and writes through a TrackLocalStaticRTP that can bind to multiple
PeerConnections, making encoded-payload fanout explicit.
This certainty moves more responsibility into the application. Pion's default interceptors provide NACK, RTCP reports, statistics, and transport-wide feedback, but an external encoder still needs explicit send-side bandwidth estimation, aggregation of both edge targets, encoder bitrate control, PLI handling, and bounded RTP/RTX queues. The already bounded #23/#28 ladder uses the same minimum-edge safety rule and must not invent a custom SRTP, ICE, or congestion protocol. A product route must follow ADR-0007 instead.
Fixed-HIGH Product-Wiring Attempt
ADR-0006 retains one narrow candidate: fixed VP8 1280x720@30 with a 3 Mbps
ceiling, one WebCodecs encoder object, at most two independent Pion legs, the
strict ordinary signaling wire, unmodified viewers, read-only feedback, and no
audio or automatic LOW. This is a proposed test boundary, not current product
behavior or hardware-encoder evidence.
The 2026-08-20 local delivery checkpoint rebases that candidate onto the sole
current access contract: screener-v2, site-access Cookie authentication,
explicit private-link creation, fragment-only Viewer grants returned to the
local Host, and STUN-only ordinary ICE. Native creation alone requests a fixed
300-second provisional room. It remains random and memory-only even with SQLite
configured: the current Host session suppresses the reclaim deadline, its
generation-matched disconnect resets the five-minute window, the ordinary
transient room TTL still caps the room, and restart drops it. A pre-auth
connection or authentication failure gets one same-room/token/client-generation
retry without a second room POST. SQLite remains v2 and ordinary Web creation is
unchanged.
Android stop/capture-failure cleanup keeps the established signaling socket until
its single-thread teardown sends abandon-room and then performs a normal close;
pending-work cancellation only blocks callbacks and cancels active HTTP. No ACK
is awaited. A provisional room whose WebSocket handshake never opened remains
bounded by the existing 300-second reclaim window.
HTTP statuses, Cookie attributes, create-room responses, Host authentication,
and ignored Viewer evidence are strict and bounded; errors retain only fixed categories.
Focused Go and TypeScript checks pass. The overbroad unused gate/probe framework
stays deleted; the current command consumer is limited to the executable runner
and sanitized stage ledger required by the next authorized run.
The one authorized 2026-08-20 current-wire attempt used Chrome 151 on Windows
amd64, a temporary non-default Chrome profile, a real animated Chrome tab, and
an isolated local Node server with an in-memory RoomStore and peer assistance
disabled. It did not contact production or SQLite. Retained history booleans
show that the source and Sender pages loaded and no Viewer page was created. The
runner reported failedStage=node-host after its bounded 20-second Sender-start
interval because it did not observe the combined Sender-ready and Go source-RTP
condition.
This is no-go-unclassified, not evidence that the Node Host path itself
failed. The timeout branch did not retain a final Sender DOM/counter sample, so
it cannot locate the break among getDisplayMedia request/resolve, Host
admission/create, WSS authentication, local bridge connection, first encoded
chunk, or Go source RTP. There was no retry or timeout adjustment. Viewer auth,
offer/answer/ICE, Pion bound-edge output, Viewer inbound/decode/render, two-edge,
and FIFO evidence were never attempted. A later run needs separate authorization
and an unconditional stage-1 final-negative ledger before it may create one
Viewer.
That local-only runner is now the current npm run gate:native-one-viewer
consumer. It requires an explicit Chrome executable environment path and uses
the task-local Go executable or task-specific PATH; neither path is committed.
Each monotonic Sender-start transition appends and flushes one bounded JSON
record containing only booleans and capped counters. A pure timeout test proves
that capture, admission/create, Host WSS, bridge, fixed-HIGH, first encoded
chunk, Go-ingest, and source-RTP state cannot be erased by a later failed sample.
The one-Viewer signaling/media waits likewise preserve their latest sanitized
sample in the final report. They now accept evidence only from one frozen
signaling socket/auth/opaque-connection ordinal, one PeerConnection/video-track
ordinal, and the same Pion slot/edge generation across signal and media stages.
The raw connection ID remains page-local. Every CDP RPC/sample is capped by the
remaining stage deadline. Final status is written only after bounded process-tree
exit and closed-port polling, followed by an exact system-Temp path audit,
recursive reparse-point rejection, profile deletion, and absence verification;
any cleanup failure is fail-closed. Microsoft documents /T as terminating a
task's child processes and ReparsePoint as the filesystem attribute used for
these special entries. Pure tests cover hung sampling, cross-PC evidence,
cleanup-before-pass, profile path bounds, and deletion failure. Sources were
rechecked 2026-08-20.
One separately authorized second current-wire run used the frozen gate once and
did not retry or adjust a threshold. Its append-and-flush ledger reached sequence
7 and retained positive booleans for capture request/resolution, site access,
private room creation, Host WSS authentication, bridge readiness, fixed VP8
1280x720@30/3 Mbps config acceptance, one encoder object, and entry into the
first WebCodecs output callback. The ledger serialized zero media counters but
did not retain whether diagnostics arrived, so those values do not prove that
Go reported zero. The runner failed closed at sender-start; it never created
the Viewer page and did not
exercise Viewer auth, SDP/ICE, Pion bound-edge output, decode/render, a second
Viewer, or FIFO. Cleanup was complete before the report was finalized: Chrome
and Native exited, the isolated Node listener and all three random loopback
ports closed, and the exact task profile passed a non-reparse audit and was
removed.
The result narrows but does not classify the break. The gate increments its
encoded-output observation before it calls the product output callback, and that
run did not retain whether the current local media WebSocket attempted, returned
from, or threw during the binary frame send. Static source comparison shows a
matching binary message type, 17-byte big-endian header, one-MiB payload limit,
and VP8 frame decode on both sides. A focused test now drives the real local
/media WebSocket through ready, fixed config acceptance, one same-contract
binary frame, decode, fanout, and positive framesWritten plus source-RTP packet
accounting. Pion's unbound static RTP track also returns no error. This proves
the current envelope is consumable by the current Go handler; it does not prove
that the retained browser called or returned from the product send.
The concrete P1 defect at this boundary was silent handling of every unexpected
post-config WebSocket read error. The handler now emits one fatal with fixed
message local media bridge read failed only while the app context is active
and the close status is neither normal nor going-away. It never includes the
underlying error or close reason. Focused real-WebSocket tests cover an abnormal
post-config close, normal close, and app shutdown. All Go tests, vet, Windows
amd64 no-CGO build, TypeScript typecheck, and the relevant bridge probe/ledger
tests pass.
One authorized evidence-clarification run then used the corrected tracked gate
exactly once with the same fixed VP8 1280x720@30, 3 Mbps, one-Viewer boundary,
Chrome 151, one in-memory loopback room, and no peer assistance. It retained the
start sequence through one generation-1 binary super.send() return, then
observed no diagnostics or post-send diagnostics, zero encoder errors, and at
least one sanitized fatal marker. The media-counter zeros are initial ledger
values, not Go reports. The gate failed at sender-start and did not create a Viewer.
Cleanup passed 5/5 before final failure. No retry, threshold change, H.264,
second Viewer, FIFO, or production run followed. The result remains
no-go-unclassified: the fatal marker and missing diagnostics do not prove where
or why the product path stopped, so no underlying close or raw cause may be
inferred.
A later static follow-up identified a deterministic source fatal candidate, but
the retained run did not preserve the fatal category needed to attribute its
failure to that branch. WebCodecs defines EncodedVideoChunk.duration as
nullable and copies output timestamp and duration from the input VideoFrame;
it does not establish the prior product assumption that the next timestamp must
be at least the previous timestamp plus duration. The local sender substitutes
33,333 microseconds when duration is absent, so ordinary capture jitter such as
1,000,000 then 1,033,000 microseconds previously reached encoded frame timestamps overlap despite strictly increasing source time.
The source candidate now packetizes the first frame without advancing Pion's
clock, then advances it by each positive adjacent source-timestamp delta before
packetizing the next frame. Reported duration remains only for positive
dropped-source-time diagnostics; equal or decreasing timestamps still fail
closed. Focused timeline tests cover shorter-than-duration jitter, dropped
source time, non-increasing input, and a positive delta below one 90 kHz sample.
A real /media handler test carries the two jittered frames through decode and
fanout with two frames written and positive source RTP. All Native Go packages
pass. These checks prove that specific fatal path is removed; the later bounded
loopback smoke below supplies one Viewer delivery proof but does not classify the
retained fatal run or establish broader Native acceptance.
The WebCodecs and pinned Pion packetizer sources were rechecked 2026-08-20.
A bounded follow-up smoke on 2026-08-20 then exercised the complete one-viewer
loopback path with Chrome 151, fixed VP8 1280x720@30, and peer assistance off.
The Sender reached 30 written frames and 85 source RTP packets with zero fatal or
encoder errors. The Viewer authenticated, completed offer/answer/ICE, received
877 packets (842,346 bytes), and advanced from 0 to 299 decoded and rendered
frames at 1280x720. The gate stopped only because its Pion outbound check sampled
the same two-second diagnostics snapshot before it refreshed (pionPacketDelta=0);
that residual probe timing does not invalidate the independent inbound/decode/
render counters, but it leaves a fresh Pion outbound delta unretained.
The gate probe now treats trickled candidates before the first offer, and a development-only pre-offer control-socket replacement, as one logical generation; after an active offer/PeerConnection, socket or connection changes still fail closed. This is test-harness evidence, not a runtime protocol relaxation. No second Viewer, FIFO, hardware, endurance, public-network, or packaged-native run followed.
The frozen probe continues to bind the first actual local media WebSocket as gate-local generation 1. A second bridge generation saturates at 2, stops accumulating the first generation's counters, and fails the Viewer signal, Viewer media, and final-success checks. Pure tests cover success, throw, and late replacement without retaining a URL, payload, token, SDP, candidate, IP address, or raw error.
Chromium documents the tab-capture auto-selection switch as a test-only aid,
and Chrome requires a non-default user-data directory for remote debugging from
Chrome 136. Those constraints explain the isolated harness setup; they do not
prove that getDisplayMedia resolved in the first failed current-wire run.
Static inspection of the pinned Pion v4.2.18 TrackLocalStaticRTP.WriteRTP shows
that it iterates the
current bindings and returns no error for an empty binding set. This excludes a
pre-Viewer no-binding write as the likely fatal break; it is not runtime proof
of Go ingest or source RTP. Sources were rechecked 2026-08-20.
The earlier authorized 2026-08-19 local product gate is
no-go-unclassified:
| Checkpoint | Retained evidence |
|---|---|
| Ordinary Node server | The local listener started with peer assistance and TURN disabled. No raw signaling frames were retained. |
| Native room/host | /api/start returned an invite, which in the attempted branch followed room creation and host signaling authentication. |
| Local encoder | Config acknowledgement preceded construction; the probe observed one VideoEncoder object and encoded output. Helper ingress, frame decode, and source RTP were not proven. |
| Viewer page | The page and probe loaded, but the 30-second combined decoded-and-rendered condition timed out. |
| Downstream lifecycle | Viewer auth, peer-joined, SDP/candidates, PC states, source RTP/edge packets, inbound RTP, video readiness, and console state were not retained. |
For that retained run, the first missing evidence checkpoint was viewer
authentication, not a proven authentication failure. The harness discarded each false sample; its reused
progress() path can omit a connection after a swallowed getStats() error;
and render evidence had no readiness/current-time/video-dimension fallback.
The timeout therefore cannot locate the runtime break or rule out a probe-only
false negative. The static code review found no obvious protocol disconnect,
which is not runtime evidence.
No second viewer, two-edge proof, third-viewer waiting/FIFO promotion, or direct/TURN pair ran. Do not treat the attempted branch as usable or mergeable product code. ADR-0006 owns the separately authorized staged revalidation and exact stop line; this research does not redefine it.
Stacked Validation Ladder
These Draft PRs are deliberately stacked research, not six product features:
| PR / commit | Bounded gate | Result |
|---|---|---|
#16 / 5b09f0a |
One Pion RTP write across two independent transports | Equivalent payload reached two transport-local SSRCs. There was no encoder or browser. |
#18 / 80f65d0 |
Synthetic WebCodecs VP8 chunks through Pion to two Chrome receivers | One encoder object produced 120 inputs/outputs and both browsers decoded; this was an offline fixture, not physical-encode evidence. |
#22 / 8121b69 |
Continuous 320x180@30 live bridge for about 12 seconds | One encoder object sent 360 chunks; each viewer decoded and presented 331 frames, with encoder/native queue peaks of one. |
#23 / eb9aabe |
Merged PLI/FIR policy, min-of-two target policy, and independent 512-packet NACK/RTX state | Policy traces passed, but stock Pion GCC plus negotiated RTX failed with unknown ssrc: 2001. This composition is no-go. |
#25 / a6c3456 |
No-RTX primary-SSRC replay under one controlled leg loss | Leg 1 emitted one NACK and one replay with fresh TWCC, then decoded another 278 frames; leg 2 stayed clean. This can distort RTCP loss accounting. |
#28 / aad560e |
Live two-leg stock-GCC target applied to the same encoder object, then one controlled loss | The bounded gate passed. Both estimates happened to be 600 kbps, so heterogeneous-estimate behavior remains unproven. |
Final Live Gate Evidence
The sole authorized #28 browser run used Headless Chrome 151 and Pion WebRTC
v4.2.18 on Windows amd64. It ran 1280x720@30 for 12.972 seconds with 390
scheduled inputs and 390 outputs from one VideoEncoder object. The encoder
queue peaked at 1/4, the native queue at 1/8, and the WebSocket buffer at
12,467/524,288 bytes; no encoder or socket drop occurred.
Both legs returned real Transport-CC before target selection. Their final stock
GCC estimates were both 600 kbps. The coordinator took the minimum, published
one 600 kbps target, and the host serialized flush(), configure() on the
same encoder object, and a forced key frame to acknowledge the change from the
initial 1.2 Mbps ceiling.
After acknowledgment, the boundary dropped one leg-1 primary packet. Chrome sent one NACK and Pion replayed the same primary RTP identity with a new TWCC sequence; leg 2 recorded no drop, NACK, or replay. Both viewers decoded another 359 frames after the shared recovery marker. This is a go result only for the bounded live target plus primary-SSRC recovery candidate.
Product Quality Direction
PR #28 establishes only that one live VideoEncoder object accepted one
conservative feedback-derived reconfiguration while feeding two transports. It
does not establish heterogeneous feedback behavior and must not evolve into a
room-wide minimum controller.
ADR-0007 keeps stock WebRTC GCC per direct/peer path. Each SFU path starts with
a HIGH ceiling and built-in BWE selects from one shared HIGH+LOW pair. App
evidence affects topology eligibility and diagnostics, not ordinary layer
selection. LOW may already be active, and idle stop depends on the resource
gate. The active representation/layer limit is two, never one per viewer; the
host still has at most two downstream media edges.
If a qualified hardware/power-efficient LOW path is unavailable or its
measured encoder/CPU/GPU game or upload load is unacceptable, LOW fails closed
for weak paths while healthy paths keep HIGH. LOW may remain active when
that measured budget passes; stopping it while idle is an optimization.
The app's HIGH/FALLBACK states and asymmetric windows only classify topology
eligibility, not media layers, and do not form a composite score. Viewer
requests are authenticated, rate-limited, deduplicated advice and need sender
transport/encode plus viewer receive/decode corroboration. UA and device
identity do not participate.
A native relay forwards the selected encoded packets and must not decode or re-encode them. An ordinary non-scalable representation cannot be forwarded into a second quality; the bounded choices are a second encode, SVC, or transcoding. ADR-0007 statically closes current Web P2P simulcast and Web/LiveKit SVC as cross-path shortcuts, but keeps pinned LiveKit exactly-two simulcast with built-in SFU bandwidth adaptation on zero-descendant leaves as the priority runtime candidate. A root-with-children downshift/evacuation gate must pass before default enablement. Explicit subscriber quality is next if built-in selection fails; manual sender activation follows if always-on cost fails; custom/native dual encode is last. A future native SVC decision may reopen only with an explicit hardware encoder contract, at most two decodable layers, one encoded output reused across direct/peer/SFU, independent path selection, and the real game/power matrix. Media Capabilities or RTCStats power-efficiency signals are diagnostics, not hardware proof; an unestablished path stays disabled rather than silently using software. Future dual-tree/striped distribution may reduce two-copy host upload toward one copy plus redundancy, but does not block dual-representation work.
Simulcast does not change this native proof boundary: one sender may negotiate
HIGH/LOW, but separate direct PeerConnections have no portable shared-encode
contract and inactive API state is not physical resource proof. ADR-0007 and
Realtime Quality Adaptation own the
static standard-path results and any future native reopen gate. This path still
requires measured per-representation traffic/resources and cannot bypass #28's
stock-GCC/RTX stop line.
2026-08-21 Evaluation Packaging Boundary
The current source now has one Windows x64 evaluation-package path. It reuses
the existing Go build and MSVC helper build, places the two executables beside
each other, embeds the exact Git revision, adds an internal SHA256SUMS.txt,
and publishes the ZIP with an adjacent SHA-256 file.
screener-sender.exe --version is the non-interactive package smoke. This does not add an installer,
Electron, auto-update, signing, a bundled server, codec matrix, or release.
The workflow uses the official windows-latest image, whose current manifest
includes VSWhere, the x64 Visual C++ tools, and Windows 11 SDK, and the official
immutable actions/upload-artifact@v7 path with missing-file failure, zero
second-stage compression for the precompressed ZIP, and seven-day retention.
GitHub requires authentication to download the resulting artifact. The
workflow is path-filtered on pull requests and main, with manual dispatch for
an exact retained commit. Sources were checked 2026-08-21.
The linked-binary audit covers 23 modules: coder/websocket is ISC; the 16 Pion
modules are MIT; google/uuid, wlynxg/anet, and the four golang.org/x modules
are BSD-style. Every linked module exposes a recognized root license file. The
packager derives the list from go list -deps, copies those exact files plus
the Go toolchain license, and fails if a linked module has no license file. No
GPL/AGPL reference or proprietary Oopz code enters the package.
The project distribution license remains undecided. The Actions artifact is therefore labeled evaluation-only and grants no project redistribution right; GitHub Release publication remains blocked on the license decision. This bounded trial artifact does not change ADR-0006's product No-Go status.
Product Stop Line
The stock Pion GCC plus negotiated RFC 4588 RTX composition is
no-go-stock-pion-gcc-rtx; do not work around it with a custom pacer,
congestion controller, interceptor fork, or private transport. The no-RTX
primary-SSRC path stays research-only because it sacrifices retransmission-
specific receiver statistics and can distort RTP/RTCP loss accounting.
No stacked PR is connected to Screener's product path, capture path, or audio path. Before product consideration, a target native sender must still prove one physical encoder invocation on representative hardware, live PLI/FIR-to-encoder control, heterogeneous downstream estimates, bounded burst and sustained loss, audio/A-V synchronization, reconnect isolation, browser diversity, lifecycle, and sustained CPU/GPU, memory, latency, quality, and upload measurements. A third host edge, custom RTP/SRTP, or a custom congestion-control framework remains out of scope. The #28 minimum-of-two policy is also out of scope for product code; retaining its evidence does not retain its policy. Ordinary Web and Native peer ICE stays STUN-only; optional selected-edge TURN follows the shared controller only after SFU/UDP fails and needs its own bounded transport gate.
Primary Sources And License Boundary
- libwebrtc PeerConnection factory injection
- libwebrtc VideoEncoder API
- libwebrtc license and PATENTS
- Windows Graphics Capture
- Media Foundation
MFTEnumEx - Media Foundation
ICodecAPI::IsSupportedandIsModifiable - Media Foundation H.264 encoder
- Media Foundation low-latency codec property
- Media Foundation force-keyframe property
- WebRTC video codec requirements, RFC 7742
- WebRTC congestion control requirements, RFC 8836
- Pion track fanout implementation
- Pion v4.2.18 pinned track implementation
- Pion send-side bandwidth estimator
- Pion WebRTC license
- WebCodecs
- NVIDIA NVENC application note
- Agora Windows screen sharing
- Agora Windows encoding preference
- Oopz help center
- W3C WebRTC Statistics
- W3C WebRTC SVC
- W3C Media Capabilities
- W3C WebRTC simulcast
- Pion WebRTC v4.2.18
- Pion Interceptor v0.1.47
- Chromium Chrome test switches
- Chrome remote-debugging profile requirement
- Microsoft
taskkill - Microsoft
FileAttributes.ReparsePoint - RFC 4585 RTP/AVPF feedback
- RFC 4588 RTP retransmission
- RFC 8888 congestion-control feedback
- Electron desktop capture
- Android media projection
- Android 14 app screen sharing
- Android media-projection foreground service
- Android
MediaCodecInfo - Android
MediaCodecList - libwebrtc
ScreenCapturerAndroid - libwebrtc
DefaultVideoEncoderFactory - libwebrtc
HardwareVideoEncoderFactory webrtc-sdk/androidwebrtc-sdk/androidlicense- libwebrtc license
- OkHttp license
- kotlinx.serialization license
- Android Kotlin/AGP compatibility
- Android Gradle Plugin 8.10 compatibility
- Apple ScreenCaptureKit
- Apple iOS ScreenCaptureKit sample
- Apple required hardware encoder key
- Apple hardware encoder readback
- GitHub Actions artifact upload
- GitHub Windows 2025 runner image
- PowerShell
Compress-Archive - Go license
The current Go candidate directly uses Pion (MIT) and coder/websocket (ISC). The evaluation package generates and verifies notices for the Go runtime and all linked direct/transitive dependencies. Choose the project license before a formal release or redistribution grant. libwebrtc/H.264 remains a separate future route requiring its own third-party notice and patent/licensing review. No source code from these projects was copied into Screener.