* gateway tests: the quiet mid-reply tests wait for, and count, the keepalive after the vendor's first words, as a held stream's before them is the agent's too (TestQuietStreamMidReplyKeptAlive failed once on main at GOMAXPROCS=2, load ~30)
The failing body began ": keepalive" before the role chunk and "hel".
That ordering is allowed, not a bug: quietFast lets watch keep the agent
alive 40ms into the try, and a vendor slow to answer (status 0, nothing
held) or one that flushed response.created and paused before "hel" (only
the role chunk, a lead, held) gets the held stream's keepalive first, as
TestSilentHeldStreamKeptAlive requires. Content that reaches the
holdWriter is scanned and flowed under h.mu, which keepQuiet and
keepAlive take, so no keepalive goes out after content the writer has
and before it is relayed. A vendor delayed 150ms before its first bytes,
or between response.created and "hel", gives the failing body every
time, with the keepalive sent at status 0 or with only the role chunk
held.
The tests released the vendor at the first keepalive and required "hel"
before it, so a slow first write made them fail, or test the held path
instead of the mid-reply one. readQuiet now releases the vendor at the
first keepalive after the given text, and aliveAfter asserts a keepalive
between "hel" and "lo": TestQuietStreamMidReplyKeptAlive and
TestQuietStreamsKeptAliveEveryProtocol's mid-reply cases.
TestQuietKeptAliveOnlySoLong counts only the keepalives after "hel", as
the held ones before them have their own 200ms. The every-protocol check
matches `"lo"` quoted: bare, it matched the anthropic cases'
content_block.
With a 150ms vendor delay injected, the old assertions fail all 5
mid-reply cases and the new ones pass. With keepQuiet's passing-branch
keepalive removed, all 6 mid-reply tests fail, delay or not. go vet;
go test -tags nogui -race -count=20 -run
'TestQuietStream|TestSilentHeld|TestQuietKeptAliveOnlySoLong'
./internal/gateway; the whole package with go test, and as a prebuilt
binary at GOMAXPROCS=2 three times (load 18-28), all pass.
* gateway tests: TestTranslatedStreamKeepsClientAlive stops counting the client's idle timeout once it has the reply's last event (red on ubuntu CI at ef5fba2c, run 37471004500: responses_to_chat "idle_timeout=true completed=true") — the gateway writes and flushes finish_reason, usage and data: [DONE] back to back in chatEncoder.finish, then serve's bookkeeping (NoteServed, saveSticks, usage.Append) runs before the handler returns and net/http sends the stream's close. On a loaded runner that, or the test's own goroutine being held, passed the 150 ms the test still counted after [DONE]. No client's idle timeout counts that wait: Codex hangs up on response.completed, and the clients that read on to the close give minutes. Chat's marker is now data: [DONE], the stream's last event, instead of finish_reason two events before it. With a 200 ms sleep after enc.finish() on the Chat path, the old test fails 20 of 20 exactly as CI did and the new one passes 20 of 20. The new test still fails 20 of 20 with the sleep before enc.finish() (completed=false), with readSSEAlive's keepalives taken out (#436), and with the Chat keepalive followed by a blank line again ("events with no data"). go test -race -count=20 -run '^TestTranslatedStreamKeepsClientAlive$' ./internal/gateway, go vet and go test -tags nogui ./... pass.
* plugin tests: the fake plugin's windows renew at times set when the host loads it, so the gateway's TestPluginFailover passes when an hour begins between two readings of an account's usage (waitingsnow)
The fake plugin told each account's five hours to renew an hour after
its usage was read, and its week a day after. TestPluginFailover weighs
the accounts by what the plugin tells (provider.Allowances), and Smart
routing puts first the account whose week renews sooner, to the hour;
accounts alike keep their order. A request that fails on an account's
quota, or in its stream, drops that account's reading
(staleAllowance), and the next request reads it again. A 401, as in
the gone round, is failOther and drops nothing (rest,
gateway/routing.go). When an hour began between a@fake's read after
the quota round and its read after the stream round, a@fake's week
renewed in the hour after b@fake's. b@fake then went first in the gone
round, failed with a 401 and kept its first reading, so the request
with both out was tried as b, a, full, which fails the test at
plugin_failover_test.go:210. An hour that began after the first
readings but before a@fake's read after the quota round put b@fake
first in the stream round instead, which failed b@fake and read it
again too, and the test passed.
The test fails every time an hour begins between those two reads of
a@fake, and passes otherwise: the 8 such runs below failed and the
other 13 passed. The reads are 12 to 76ms apart in the runs below
without the hold, and a reviewer's -race build measured 33 to 106ms in
6 runs, so a run at a random time fails about once in 34,000 to
300,000. CI's Linux job installs bun 1.4.2 and runs the test in its
Test and Race steps. Found by a review of the tests that compare
renewals to the hour; no CI run was checked for it.
The windows now renew an hour and a day after born, when the host
loaded the plugin, however often an account is read, as a vendor's
windows renew at times of their own. Run once in a process, as CI's
Test and Race steps run it, TestPluginFailover reads its accounts from
the one host started after its plugin.Add, so they renew together. Run
again in one process (-count), a run can still weigh an account by the
previous run's host, born perhaps in the hour before, until that
account fails and is read again: provider's allowances and usage
readings outlive fresh(t) and plugin.Settle. That account then goes
first, and the test's rounds fail it and read it again before the
checks that depend on order, so it still passes; clearing those caches
is left for its own commit.
TestPluginUsage now reads a@fake's card a second time from its refresh
button, 2ms later, and wants each window to renew when it did the first
time, as a vendor's do. That is the check that fails without this
change. Its other bounds (the five hours in 50 minutes or more, the
week in 23 to 25 hours, full@fake's five hours used up) hold while the
host is under 10 minutes old; no other test reads these times.
Verified under a temporary HOME with Go's caches pinned, every test run
with -tags nogui and bun 1.4.2. With 01aaa8e9's index.js put back,
TestPluginUsage fails every run:
plugin_usage_test.go:109: a@fake's 5 hours renews at 2026-10-07
12:16:35.567 +0000 UTC read again, at 2026-10-07 12:16:35.539 +0000
UTC first
and with this one it passes, also with -count=5.
With 01aaa8e9's index.js, TestPluginFailover passes unless an hour
begins between those two reads. failgap.sh, a scratch script, builds
the gateway's test binary once and runs TestPluginFailover with the
old plugin and with this one. It makes the plugin's usage hook tell
its windows from Date.now() plus a shift, set at the first reading so
that an hour begins a set time later (Go's clock is left alone), and
logs each reading. Its copy of the test can hold 2s before the stream
round, which puts its lines 5 further down. With the hour 30ms after
the first reading, the old plugin failed 3 runs of 3, its two reads of
a@fake either side of the hour (at 23 and 42ms, 20 and 34, 18 and 37):
plugin_failover_test.go:215: fake-claude with the others out: 200
{...} (tried [b a full])
At 45ms it failed 1 of 3 (44 and 69ms). At 60, 80 and 120ms it passed
9 of 9, a@fake read twice before the hour, or once after it and b@fake
read again. Held 2s before the stream round, with the hour 50 or
1100ms after the first reading, it failed 4 of 4 (a@fake read at 24 to
34ms and 2044 to 2121ms). This plugin passed all 19 of those runs.
That shows only that the test passes with it: its windows are fixed
from born when the host loads it, before failgap's first reading moves
the clock, so the moved hour never reaches them. Held 2s with the hour
30 minutes away, both plugins passed 2 of 2. born.sh, run as a process
per run, logged the host and the born behind each of the plugin's
reads in 20 more runs of this one: 9 a run, each run's from one host
and one born. It logs the plugin's reads, not what routing weighed.
gofmt -l internal/provider/plugin_usage_test.go prints nothing. go vet
./..., go build ./..., GOOS=linux go build -tags nogui ./...,
GOOS=windows go build ./... and GOOS=windows go vet -tags nogui
./internal/provider/ pass. go test -tags nogui ./... passes, 43
packages ok, with bun 1.4.2 on PATH, and so do TestPluginFailover and
TestPluginUsage* with -race -count=20.
* gateway tests: TestTranslatedStreamKeepsClientAlive fails when the stream doesn't close within 5s of its last event, rather than waiting on it with no limit
After the reply's last event the read had no time limit, so a gateway
that never closed the stream would hang the test until the package
timeout (yetone on #1163). The idle timeout still stops at the last
event; a 5s limit on the close follows it.